Quadro de Cargas (QDG1) - TÉRREO CircuitoDescriçãoEsquemaMétodo Tensão Pot. total.Pot. total.Fases Pot. - RPot. - SPot. - TFCTFCA In'IpSeçãoIcIccDisjdV parc de inst. (V) (VA) (W) (W) (W) (W) (A)(A)(mm²)(A)(kA)(A) (%) QD1 3F+N+T B1 220/127 V 10359 6742 R+S+T 2071 2071 2600 1.000.7031.622.125117.0570 2.14 QD2 3F+N+T B1 220/127 V 49129 47469 R+S+T 15535 15068 16867 1.000.72130.093.635110.05100 3.16 QD3 3F+N+T B1 220/127 V 21180 15185 R+S+T 4756 5943 4487 1.000.7257.941.716 68.0563 2.95 QD4 2F+N+T B1 220/127 V 15975 14048 S+T 7024 7024 1.000.7240.329.025 89.0570 1.29 QD5 2F+N+T B1 220/127 V 23702 17364 R+T 8682 8682 1.000.7273.552.925 89.0570 1.68 QD6 2F+N+T B1 220/127 V 21884 19718 R+S 9859 9859 1.000.7082.257.525 89.0570 0.31 QDAr1 3F+N+T B1 220/127 V 13565 10645 R+S+T 3232 4047 3367 1.000.7254.339.125 89.0570 2.04 QDAr2 3F+N+T B1 220/127 V 17219 14715 R+S+T 4941 5226 4548 1.000.7275.154.125 89.0570 2.01 QDAr3 3F+N+T B1 220/127 V 13487 11540 R+S+T 4028 3893 3620 1.000.7258.041.716 68.0563 1.76 QDAr4 3F+N+T B1 220/127 V 18525 16075 R+S+T 5223 5223 5630 1.000.7077.554.316 68.0563 0.39 TOTAL 205026 173501 R+S+T 58325 58352 56825 Quadro de Demanda (QDG1) - TÉRREO Tipo de carga Potência instalada (kVA) Fator de demanda (%) Demanda (kVA) Chuveiros, ferros elétricos, aquecedores de água (Não residencial)37.80 60.00 22.68 Condicionador de ar tipo janela (Não residencial) 48.19 80.00 38.56 Iluminação e TUG's (Clínicas e hospitais) 50.00 40.00 20.00 17.36 20.00 3.47 Motores 48.48 42.00 20.36 Uso Especí?co 3.20 100.00 3.20 TOTAL 108.27 R Branco S Preto T Vermelho N Azul PE Verde DPS 275 V - 40 kA QDG1 QD1 6742 W 70 A Unipolar - EPR/XLPE (90°C) #100x75 25 QDAr1 10645 W 70 A Unipolar - PVC (70°C) #100x75 25 QD2 47469 W 100 A Unipolar - PVC (70°C) #100x75 35 QDAr2 14715 W 70 A Unipolar - PVC (70°C) #100x75 25 QD4 14048 W 70 A Unipolar - PVC (70°C) #100x75 25 QDAr3 11540 W 63 A Unipolar - PVC (70°C) #100x75 16 QD5 17364 W 70 A Unipolar - PVC (70°C) #100x75 25 QDAr4 16075 W 63 A Unipolar - PVC (70°C) #100x75 16 QD6 19718 W 70 A Unipolar - PVC (70°C) #100x75 25 QD3 15185 W 63 A Unipolar - PVC (70°C) #100x75 16 Potência instalada (W) R 58325 S 58352 T 56825 Total 173501 Unipolar - EPR/XLPE (90°C) 3#240(240)120mm² Conduto ø4"(PVC) 315 A Verde QM1 KW.h 315 A 60 kA 240 120 R+S+T Unipolar - EPR/XLPE (90°C) ø4"(PVC) 315 A 60 kA DPS 4x275 V - 40 kA 70 A 5 kA 25 16 Unipolar - EPR/XLPE (90°C) #100x75 (6742 W) R+S+T QD1 100 A 5 kA 35 16 Unipolar - PVC (70°C) #100x75 (47469 W) R+S+T QD2 63 A 5 kA 16 Unipolar - PVC (70°C) #100x75 (15185 W) R+S+T QD3 70 A 5 kA 25 16 Unipolar - PVC (70°C) #100x75 (14048 W) S+T QD4 70 A 5 kA 25 16 Unipolar - PVC (70°C) #100x75 (17364 W) R+T QD5 70 A 5 kA 25 16 Unipolar - PVC (70°C) #100x75 (19718 W) R+S QD6 70 A 5 kA 25 16 Unipolar - PVC (70°C) #100x75 (10645 W) R+S+T QDAr1 70 A 5 kA 25 16 Unipolar - PVC (70°C) #100x75 (14715 W) R+S+T QDAr2 63 A 5 kA 16 Unipolar - PVC (70°C) #100x75 (11540 W) R+S+T QDAr3 63 A 5 kA 16 Unipolar - PVC (70°C) #100x75 (16075 W) R+S+T QDAr4 QDG1 (173501 W) Quadro de Cargas (QM1) - TÉRREO CircuitoDescriçãoEsquemaMétodo Tensão Pot. total.Pot. total.Fases Pot. - RPot. - SPot. - TFCTFCA In'IpSeçãoIcIccDisjdV parc de inst. (V) (VA) (W) (W) (W) (W) (A)(A)(mm²)(A)(kA)(A) (%) QDG1 3F+N+T D 220/127 V 205026 173501 R+S+T 58325 58352 56825 1.001.00331.4331.4240351.060315 0.89 TOTAL 205026 173501 R+S+T 58325 58352 56825 Quadro de Demanda (QM1) - TÉRREO Item Demanda (kVA) Cargas especiais 108.27 TOTAL 108.27 AL1 240 R+S+T Unipolar - EPR/XLPE (90°C) ø4"(PVC) KW.h 315 A 60 kA DPS 4x275 V - 40 kA 240 120 Unipolar - EPR/XLPE (90°C) ø4"(PVC) (173501 W) R+S+T QDG1 QM1 (173501 W) R Branco S Preto T Vermelho N Azul PE Verde DPS 275 V - 40 kA QM1 QDG1173501 W Unipolar - EPR/XLPE (90°C) ø4"(PVC) 240 Potência instalada (W) R 58325 S 58352 T 56825 Total 173501 Unipolar - EPR/XLPE (90°C) 3#240(240)mm² Conduto ø4"(PVC) 315 A Verde PLOTRAR COLORIDO NOTA 01 QUADROS DE CARGAS DO P AVIMENTO TÉRREO 010203040506070809 010203040506070809 B C D E F G A B C D E F G A HH PROJETO ELÉTRICO CONTRATADO: INDICADAS NO DESENHO 06/13 CLIENTE: OBRA: Número Cliente: EST ESCALA: DESENHO NÚMERO: MOD: FOLHA: VERIFPRO APROV DATA NOME REVIS. PROJETO: 00001 REFERÊNCIA: (1°DIEDRO)UNIDADE: (EXCETO INDICADO) cm REVISÃO: 00 TÍTULO: 6 ELE CREA: JÚLIA VILELA DE FARIA 86/2024 18/11/2024 MINISTÉRIO DA SAÚDE UBS 4 SECRETARIA DE ATENÇÃO ESPECIALIZADA A SAÚDE CREA/MG - 313914/D 18/11/2024